Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Health Phys ; 126(4): 207-215, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38300139

ABSTRACT

ABSTRACT: Radioactive materials and ionizing radiation have both medical value and disease risks, necessitating radiation dose measurement and risk reduction strategies. The International Commission on Radiological Protection (ICRP) lowered the lens of the eye exposure limit, leading to Japan's revised "Ionizing Radiation Ordinance." However, the effects on radiation exposure in medical settings and compliance feasibility remain unclear. To examine the impact of the revision to the "Ionizing Radiation Ordinance" and use it for measures to reduce exposure to radiation, a comprehensive analysis was conducted on data collected from Nagasaki University Hospital, Hiroshima University Hospital, and Fukushima Medical University Hospital in 2018, 2020, and April to September 2021. This included information on age, sex, occupation, department, and monthly radiation doses of workers, aiming to assess the impact of the revision to the "Ionizing Radiation Ordinance" on radiation exposure before and after its enforcement. Out of 9,076 cases studied, 7,963 (87.7%) had radiation doses below the measurable limit throughout the year. Only 292 cases (3.2%) exceeded 1 mSv y -1 , with 9 doctors and 2 radiological technologists surpassing 5 mSv y -1 . Radiological technologists showed significantly higher doses compared to doctors, dentists, and nurses (p < 0.01), while male subjects had significantly higher exposure doses than females (p < 0.01). No significant changes in radiation exposure were observed before and after the revision of the Ionizing Radiation Ordinance; however, variations in radiation exposure control were noted, particularly among nurses and radiological technologists, suggesting the impact of the revision and the need for tailored countermeasures to reduce radiation dose in each group.


Subject(s)
Lens, Crystalline , Occupational Exposure , Radiation Exposure , Female , Humans , Male , Japan , Lens, Crystalline/radiation effects , Radiation Exposure/adverse effects , Health Personnel , Radiation, Ionizing , Occupational Exposure/analysis , Radiation Dosage
2.
Eur J Med Res ; 29(1): 32, 2024 Jan 06.
Article in English | MEDLINE | ID: mdl-38184638

ABSTRACT

BACKGROUND: Transthyretin amyloid cardiomyopathy (ATTR-CM), characterized by the extracellular deposition of an insoluble amyloid protein in the heart, is one of the main causes of heart failure in elderly patients. In this study, our primary objective was to explore the diverse applications and temporal significance of 1-h and 3-h imaging using 99mTc-PYP in the context of ATTR-CM. Additionally, we compared tracer kinetics in the heart and bone to comprehensively assess the diagnostic advantages and time-related considerations associated with these two incubation periods. METHODS: Twenty-seven patients at Nagasaki University Hospital who underwent 99mTc-PYP planar, and SPECT cardiac imaging were classified into two groups (ATTR-CM-positive and -negative groups) based on the American Heart Association statement. Cardiac retention was assessed with both a semiquantitative visual score and a quantitative analysis. To assess bone accumulation, a ROI with an equal volume was drawn on the sternum and calculated as the bone-to-contralateral ratio (B/CL). We also evaluated correlation between heart-to-contralateral lung (H/CL) ratio and left ventricular wall thickness. RESULTS: Among patients who underwent 99mTc-PYP imaging, the H/CL ratio was significantly higher at 1 h than at 3 h regardless of the group (from 2.20 ± 0.36 to 1.99 ± 0.35, p < 0.01 in the positive group and from 1.35 ± 0.12 to 1.19 ± 0.21, p = 0.01 in the negative group). The gap of H/CL between highest H/CL of negative case and lowest H/CL of positive case was narrower in 3 h. On the other hand, correlation between H/CL and left ventricular posterior wall thickness tends to be clearer in 3 h (p = 0.12, r = 0.30 for 1 h, p = 0.04, r = 0.39 at 3 h). CONCLUSION: Our study suggests that both 1-h and 3-h incubation times for 99mTc-PYP imaging have different benefits for ATTR cardiac amyloidosis. A one-hour incubation may be preferable for differential diagnostic purposes, while a three-hour incubation may provide greater utility in evaluating disease severity.


Subject(s)
Amyloidosis , Heart Failure , United States , Aged , Humans , Technetium Tc 99m Pyrophosphate , Diagnostic Imaging , Amyloidosis/diagnostic imaging , Heart/diagnostic imaging
3.
Ann Nucl Cardiol ; 9(1): 48-53, 2023.
Article in English | MEDLINE | ID: mdl-38058579

ABSTRACT

Background: Technetium-99m pyrophosphate single photon emission computed tomography (99mTc-PYP SPECT) imaging is widely used to diagnose cardiac amyloidosis, a disease characterized by amyloid protein deposits in the myocardium. The effects of viewing perspectives on interobserver agreement in the interpretation of 99mTc-PYP SPECT images for the diagnosis of cardiac amyloidosis remain unclear. Methods: A retrospective analysis of 32 consecutive patients who underwent 99mTc-PYP imaging for the diagnosis of cardiac amyloidosis at Nagasaki University Hospital between October 2017 and February 2020 was performed. Four evaluators independently reviewed coronal, sagittal, and transaxial images and then all images together and made a categorical diagnosis based on predefined criteria. Interobserver agreement was analyzed using Cohen's Kappa analysis. Results: Kappa coefficient values in the four-grade grading system (grades 0-3) ranged between 0.31 and 0.95, while those in the binary grading system (positive/negative) ranged between 0.88 and 1. The sagittal view showed the highest value in the four-grade grading system (0.95) and the lowest in the binary grading system (0.88). The transaxial view was more likely to show a consistently high kappa value in both the four-grade and binary grading systems. The use of the multiplanar view reduced the number of subjects classified as grade 1. Conclusion: Our study demonstrates that the transaxial view provides the most consistent interpretation of 99mTc-PYP SPECT images for the diagnosis of cardiac amyloidosis. The use of the multiplanar view may also reduce equivocal interpretations, which are graded as grade 1. Further studies with larger sample sizes and a quantitative analysis are needed to confirm the present results.

SELECTION OF CITATIONS
SEARCH DETAIL
...